– 13 –
TIME
Time is displayed in “hours & minutes”. When the unit
is fi rst powered on, the time display shows “--:--”. To
increase time, turn knob to the right, and to decrease
time, turn knob to the left. When the knob stops, the
displayed time countdown then begins.
When the time counts down to "00:00", the display will
fl ash and the operator will be alerted with a buzzer and
lights (based on parameter settings). To add time, turn
the knob to the right to the desired additional time. The
buzzer stops when additional time is added. To mute
the buzzer function, turn the knob to the left with the
door shut. The display lights will still fl ash. Opening
the door stops the time and the buzzer. Shutting the
door will reset the time function to the last time setting.
When the door is opened during an active countdown time, the time pauses and restarts when the door
is shut.
At the end of a time cycle “00:00” fl ashes. If no adjustment of the time knob is made and “00:00” is still
displayed when the door is shut, the last time setting is automatically recalled and the time countdown
starts again.
To manually return to a no time setting, turn the timer knob to the left until --:-- is displayed. The time
function does not control or affect the heating or humidity functions.
Setting time works the same when the door is either open or closed. Time does not count down when
the door is open.
HUMIDITY
The humidity set point has an automatic setting based
on temperature selection. The operator can increase
or decrease the humidity setting manually by turning
the knob more than 1 indent to the left to decrease or
more than 1 indent to the right to increase. Turning only
1 indent displays actual oven cavity humidity.
Recall of the last humidity setting also occurs when the
temperature is switched off and then back on. Default
settings are used unless a manual humidity setting
adjustment is made.
NOTE: When checking actual humidity the display may
show " - " while the sensor is initializing.