Vulcan-Hart SG4C ML-114876 Convection Oven User Manual


 
— 6 —
INSTALLATION CODES AND STANDARDS
Vulcan ovens must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223.1 (latest edition). Copies may be obtained from The American
Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.
3. National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. CSA B149.1 Natural Gas and Propane Installation Code.
3. CSA C22.1 Canadian Electrical Code.
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,
Mississauga, Ontario, Canada L4W 5N6.
INSTALLING BASIC OVEN
The basic oven must be installed on legs, casters or mounted on a modular stand. Installations on
concrete bases or other supports restricting air circulation underneath the oven is not advisable and
may void the warranty.
Ovens Mounted on Casters
Ovens mounted on casters must use a flexible connector
(not supplied by Vulcan) that complies with the Standard for
Connectors for Movable Gas Appliances, ANSI Z21.69 •
CSA 6.16 and a quick-disconnect device that complies with
the Standard for Quick-Disconnect Devices for Use With
Gas Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate
means must be provided to limit movement of the appliance
without depending on the connector and the quick-disconnect
device or its associated piping to limit appliance movement.
Attach the restraining device at the rear of the oven as
shown in Fig. 1.
If disconnection of the restraint is necessary, turn off the gas
supply before disconnection. Reconnect this restraint prior
to turning the gas supply on and returning the oven to its
installation position.
Separate instructions for installing casters to the oven are
included with the casters.
Note: If the oven is installed on casters and is moved for any reason, it is recommended that the oven
be releveled front to back and side to side for even baking.
Fig. 1
CONNECT GAS
LINE STRAIN
RELIEF HERE
PL-52805