Specifications
NOTE
: All charging specifications are at nominal conditions: ambient temperature of 77 °F (25 °C), 120 VAC, 60 Hz input, unless otherwise specified.
Charger Specifications Freedom SW 2012 Freedom SW 2024 Freedom SW 3012 Freedom SW 3024
Charging method Three-stage charge (Bulk, Absorption, Float)
Two-stage charge (Bulk, Absorption)
The default charging method is three-stage.
Without a battery temperature sensor Three settings with the following temperature values:
Cool 50 °F (10 °C)
Warm 77 °F (25 °C)
Hot 104 °F (40 °C)
The default setting is Warm and it can only be changed by the factory, a dealer, or a service centre.
With a battery temperature sensor (included) The temperature compensation coefficients on a
12-volt battery are as follows:
Flooded: 27 mV × (25 °C – BTS °C)
Gel: 27 mV × (25 °C – BTS °C)
AGM: 21 mV × (25 °C – BTS °C)
The temperature compensation coefficients on a
24-volt battery are as follows:
Flooded: 54 mV × (25 °C – BTS °C)
Gel: 54 mV × (25 °C – BTS °C)
AGM: 42 mV × (25 °C – BTS °C)
Output current (maximum) 100 ADC 50 ADC 150 ADC 75 ADC
Output voltage 12 VDC 24 VDC 12 VDC 24 VDC
Output voltage range 5–16 VDC 12–32 VDC 5–16 VDC 12–32 VDC
Equalization cycle Automatic, Manual by Xanbus SCP Automatic, Manual by Xanbus SCP
Optimal charging efficiency > 85% > 85%
AC input power factor (at full charge rate) > 0.98 > 0.95
AC input current 24A max. (including pass-thru) 24A max. (including pass-thru)
AC input voltage 120 VAC 120 VAC
AC input voltage range 85–140 VAC 85–140 VAC
Dead battery charge voltage > 5 VDC > 12 VDC > 5 VDC > 12 VDC
Supported AC input types Single input (up to 30 amps) Split phase (up to 30 amps per line)
Dual input (up to 30 amps per line)
Freedom SW 3K2K InvChg Owners Guide.book Page 83 Thursday, July 31, 2014 1:42 PM