Bunn CDS-3 Beverage Dispenser User Manual


 
22
4. Disconnect the auger motor terminal from the
terminal on the main wiring harness.
5. Remove the three remaining #8 locking screws
securing the auger motor mounting bracket to
cooling drum mounting bracket.
6. Remove motor with mounting bracket, drip tray, split
pin and torsion spring bearing as an assembly.
NOTE: When removing or installing the motor be sure
the split pin in the motor shaft is turned to a position
that will clear the torque sensor circuit board.
7. Install new motor with mounting bracket, drip tray,
split pin and torsion spring bearing using three #8
locking screws onto the cooling drum bracket.
8. Install the auger motor capacitor on the lower right
side of the auger mounting bracket, using the re-
maining #8 locking screw.
9. Connect the auger motor terminal to the terminal
on the main wiring harness.
10. Refer to Fig. 2 when reconnecting the wires.
FIG. 2 AUGER MOTOR TERMINALS
P1321
Location
The auger motors are located at the upper rear of
the dispenser chassis inside the auger motor covers.
Test Procedures
1. Disconnect the dispenser from the power source.
2. Disconnect the wires from the motor to be test-
ed.
3. With a voltmeter, check the voltage across the
white/brown wire for the left motor, the white/blue
wire for the right motor, or the grey wire for the
center motor and the white/black wire. Place the
appropriate auger switch in the “-” (“ON”) position.
Connect the dispenser to the power supply. The
indication must be:
a) 120 volts ac for 120 volt models.
b) 230 volts ac for 230 volt models.
4. Disconnect the dispenser from the power supply.
If voltage is present as described, replace the motor.
If voltage is not present as described, refer to the Wiring
Diagram and check the dispenser wiring harness.
Removal and Replacement
1. Remove the two #8 locking screws securing the
auger motor cover to the cooling drum mount as-
sembly.
2. Remove the cover and set aside for reassembly.
3. Remove the #8 locking screw on the lower right
side of the auger motor mounting bracket securing
the auger motor run capacitor. Set capacitor aside
with wires attached.
SERVICE(CONT.)
AUGER MOTORS
FIG. 1 AUGER MOTORS
P1341
27646 022500