4
USER NOTICES (CONT.)
CHARGE
Type R22, Amount 8.4 oz
Design Pressures: High 210 Low 32
AFTER CLEANING &
BEFORE REASSEMBLY
LUBRICATION
1
2
3
27664.0000D 5/97 © 1996 BUNN-O-MATIC CORPORATION
1. Apply lubricant* on lip of auger seal where
contact is made with cooling drum.
2. Apply lubricant* on outside surface of
cooling drum seal or inside bore of hopper.
3. Apply lubricant* over o-rings on faucet spool
before inserting into faucet housing.
* Refer to product literature for Bunn
approved lubricant.
27664.0000
27444.0000 (CDS-2 Only)
28519.0000 (CDS-3 Prior to S/N CDS0019500)
CHARGE
Type R404A, Amount 25 oz
Design Pressures: High 320 Low 44
CHARGE
Type R404A, Amount 9.5 oz (269 gm)
Design Pressures:
High 215 psi (15 bar) (1.48 MPa)
Low 40 psi (3 bar) (0.28 MPa)
29373.00000 (CDSA-2 Only)
CHARGE
Type R404A, Amount 22 oz
Design Pressures: High 380 Low 52
29424.0000 (CDS-3 S/N CDS0019500 - UP)
27646 022500