37
FIG. 28 DISPENSER ON/OFF SWITCH
TERMINALS
P1337
SERVICE (cont.)
DISPENSER ON/OFF SWITCH
FIG. 27 ON/OFF SWITCH - DISPENSER
P1343
Location:
The dispenser ON/OFF switch is located inside
the dispenser drawer on the left front of the control
panel.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the black wire from the switch and
white/black from contactor located on the outside
bottom of the component bracket .
3. With a voltmeter, check the voltage across the black
and the white/black. Connect the dispenser to the
power source. The indication must be:
a) 120 volts ac for 120 volt models.
b) 230 volts ac for 230 volt models.
If voltage is present as described, reconnect the white/
black wire to the contactor and proceed to #5.
If voltage is not present as described, refer to the Wiring
Diagram and check the dispenser wiring harness.
5. Disconnect the white/green wire from the ON/OFF
switch.
6. With the ON/OFF switch in the “-” (“ON”) down
position check for continuity across the switch
terminals. Continuity must not be present when
the switch is “o” (“OFF”) down position.
If continuity is present as described, the ON/OFF switch
is operating properly.
If continuity is not present as described, replace the
ON/OFF switch.
Removal and Replacement:
1. Pull the dispenser drawer out far enough to expose
the four #8 -32 locking screws securing the switch
panel to the drawer.
2. Remove the four #8-32 locking screws.
3. Lift switch panel with wires and L.E.D./adjustment
board as an assembly.
4. Turn switch panel over and remove the wires from
the dispenser ON/OFF switch.
5. Compress the clips on the back of the control panel
and gently push switch through the opening.
6. Push the new switch into the opening, with the “o”
on the switch to the outside, until the clips snap
into position.
7. Reconnect the wires to the switch. Refer to Fig. 28
when reconnecting wires.
8. Position the switch panel inside the drawer and
secure with four #8-32 locking screws.
27646 122200