Page 36
Timer Setting:
NOTE: Prior to setting or modifying volumes, check
that the brewer is connected to water supply, the tank
is properly filled, and a funnel and server are in place.
NOTE: All volume settings must be done with the
sprayhead installed.
NOTE: The timer must be adjusted for each individual
batch setting.
1. Modifying brew volumes. To modify a brew vol-
ume, first check that the SET/LOCK switch is in the
"SET" position on the circuit board.
To increase a brew volume, place the ON/OFF
switch in the "ON" position, press and hold the START
switch until three clicks are heard. Release the switch
and press it again one or more times. (Failure to re-
lease the switch within two seconds after the third
click causes the volume setting to be aborted and pre-
vious volume setting will remain in memory.) Each
time the switch is pressed, two seconds are added to
the brew time period. Allow the brew cycle to finish in
order to verify that the desired volume has been
achieved.
To decrease a brew volume, place the ON/OFF
switch in the "ON" position, press and release the
START switch once for every two-second interval to
be removed from the total brew time period; then im-
mediately press and hold down the START switch until
three clicks are heard. Release the switch. (Failure to
release the switch within two seconds after the third
click causes the volume setting to be aborted and pre-
vious volume setting will remain in memory). Allow
the brew cycle to finish in order to verify that the de-
sired volume has been achieved.
2. Setting brew volumes. To set a brew volume,
first check that the SET/LOCK switch is in the "SET"
position on the circuit board. Place the ON/OFF switch
in the "ON" position, press and hold the START switch
until three distinct clicks are heard and then release
the switch. (Failure to release the switch within two
seconds after the third click causes the volume set-
ting to be aborted and previous volume setting will
remain in memory.)
View the level of the liquid being dispensed. When
the desired level is reached, turn the ON/OFF switch
to "OFF".
NOTE: Several ounces of water will continue to sy-
phon from the tank after turning the switch "OFF". The
brewer remembers this volume and will continue to
brew batches of this size until the volume setting pro-
cedure is repeated.
NOTE: When brewing coffee, volume will decrease due
to absorption by the coffee grounds.
3. Setting programming disable feature. If it be-
comes necessary to prevent anyone from changing
brew time once programmed, you can set the SET/
LOCK switch to the "LOCK" position. This will prevent
any further programming until switch is once again
put into the "SET" position.
SERVICE (cont.)
DIGITAL TIMER (ELECTRO/MECHANICAL ONLY)
(LATE MODELS)(cont.)
TL1 - WHI/VIO to ON/OFF Switch
TL2 - WHI to Terminal BLock (WHI Insert)
(120/208V or 120/240V Three Pole
Terminal Block)
RED to Terminal Block (RED Insert)
(200V or 240V Two Pole Terminal Block)
TL3 - WHI/ORN to Start Switch
TL4 - WHI/GRN to Dispense Valve
TL5 - WHI/YEL to Start Switch
FIG. 32 DIGITAL TIMER WIRING
P2037
27362 092900