INITIAL SET-UP
CAUTION – The brewer must be disconnected from the power source throughout the initial set-up, except when
specified in the instructions.
1. Remove the front panel beneath the sprayhead.
Models with digital brewer control assembly:
Place the tank heater toggle switch at the bottom left of the control assembly in the "OFF" position.
Models with electro/mechanical thermostats:
Rotate the control thermostat knob fully counterclockwise to the "OFF" position.
2. Connect the brewer to the power source. Water will begin flowing into the tank.
3. When water stops flowing into the tank, remove the front panel and proceed as directed.
Models with digital brewer control assembly:
Place the tank heater toggle switch at the bottom left of the control assembly in the "ON" position and replace
the front panel.
Models with electro/mechanical thermostats:
Rotate the control thermostat knob fully clockwise to the "ON" position and replace the front panel.
4. On 208V or 240V Models , wait approximately twenty-five minutes for the water in the tank to heat to the proper
temperature.
5. Place an empty server beneath the brew station. Place the Selector switch in the desired position, the ON/OFF
switch in the "ON" (upper) position and initiate a brew cycle. Each volume must be set individually.
6. Place the ON/OFF switch in the "OFF" (lower) position after water has stopped flowing from the funnel, and check
the water volume in the server. It should be 128 oz (1 gallon), 192 oz (1-1/2 gallon) or 256 oz (2 gallon).
7. (A) If not, adjust the brew timer as required. See
Adjusting Brew Volumes
for electro/mechanical brewers
.
See
Service - Digital Brewer Control Board
for DBC Brewers.
Allow the water to reheat, start, and measure another
brew cycle.
(B) If necessary adjust the needle valve to achieve water volume to be bypassed around the coffee filter in the
funnel.
NOTE: To increase the water bypass turn the needle valve counterclockwise, to decrease the water bypass turn
the needle valve clockwise. An adjustment to the needle valve will require a timer adjustment for desired
volume.
8. Repeat step 7 until the proper water volume is achieved.
9. The brewer is now ready for use in accordance with the coffee brewing instructions.
ADJUSTING BREW VOLUMES
electro/mechanical brewers
CAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement
or adjustment of any component.
NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply, the tank is
properly filled, and a funnel and server are in place.
1. Modifying batch sizes. To modify a batch volume, first check that the SET/LOCK switch is in the SET
position on the circuit board. Select the batch volume to be set. (1, 1-1/2, or 2 gallons)
NOTE: Each batch setting must be adjusted separately.
To increase a batch size. Press and hold the START or BREW switch until three clicks are heard. Release the
switch (Failure to release the switch within two seconds after the third click causes the volume setting to be
aborted and previous volume setting will remain in memory) and press it again one or more times. Each time
the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order
to verify that the desired volume has been achieved.