Cleveland Range 22CET3A Oven User Manual


 
29
system the supply piping to the tee fitting should be of at least the next largest size of pipe
to the connection provided at the steamer.
b) The steamer has two 3/4-inch NHT fittings (Standard Garden Hose fitting) for the water
connections to the water reservoir and to the condenser. These fittings are detailed as C1
and C2 in Figure 4-1. NOTE: The hose connector used must be NSF or FDA rated for food
grade service.
c) Install a manual water valve between the main cold water supply line(s) and the steamer
supply lines.
d) The National Sanitation Foundation (NSF) requires installation of a check-valve in all supply
lines in accordance with and as required by local plumbing codes.
e) The water supply line(s) should be designed so that the unit can be moved for service.
Figure 4-14 Cleveland Range Single Water Supply Arrangement
(
The strainers for this unit are preinstalled in the water inlet)
Figure 4-15 Cleveland Range Separate Water Supply Arrangement when Using
Separate Conditioned Feed Water Supply
(
The strainers for this unit are preinstalled in the water inlet)
f) A Filter Washer (dirt filter) is supplied installed in each
of the water inlets of this steamer (See Figure 4-16),
Cleveland Range part number 110987.
g) Construct all supply lines up to the point of installing the
strainer. Flush the water supply lines before connecting
the strainer.
h) Apply pipe dope or Teflon tape to any threaded pipe
connections. DO NOT USE SEALANT ON ANY
NATIONAL HOSE THREADED CONNECTION.
Steam Resevoir
Solenoid
Water Connection C1 on
Dimension Diagram
Pressure Reducer
(if required)
Main Water
Shut Off Valve
Main Cold
Water Supply
Air/Water Column
(if required)
Check Valve
Strainer
Condenser Solenoids
Water Connection C2 on
Dimension Diagram
SteamChef
¥
3
Flow
Water Connection C1 on
Dimension Diagram
Condenser Solenoids
Water Connection C2 on
Dimension Diagram
Pressure Reducer
(if required)
Main Water
Shut Off Valve
Standard Cold
Water Supply
Air/Water Column
(if required)
Check Valve
Strainer
Flow
Conditioned Cold
Water Supply
Flow
Steam Reservoir
Solenoids
SteamChef
¥
3
Figure 4-16 Filter
Washer Assembly