5
c. Place the KleanShield¥ into the steamer with
pipe extension towards the back and facing
down. Set the KleanShield¥ in place over the
corresponding pipe extending out of the bottom of
the steamer reservoir. See Figure 2-3.
d. The KleanShield¥ is installed properly when the
pipe from the KleanShield¥ is fitted into the
corresponding pipe in the bottom of the steamer
and its legs are flush against the bottom of the
steamer. See Figure 2-6.
4. Inspecting The Cooking Compartment
a. Before turning ON the power switch/lever to the
SteamChef¥ 3, the entire inside of the steamer
must be thoroughly cleaned.
b. All food debris should be wiped clean and the
drain openings and the water level sensors shall
be inspected and cleaned of any residue or
debris (See Figure 2-4).
c. The door gasket assembly, KleanShield¥, fan
guard and slide racks should be inspected for
proper installation and cleanliness. See Chapter
2, Section A, Part 3 for proper installation of the
KleanShield¥.
x To properly install the fan guard, hold the fan
guard so that the large ends of the keyholes
are towards the bottom of the steamer. Place
all four openings over the mounts located on
the rear wall of the steamer and pull it down
so that the narrow ends of the slots are pulled
tight over the mounts. See Figure 2-5.
d. Make sure that the KleanShield¥ drain is clear. See Figure 2-6.
e. It is also recommended that a small amount of water (about a quart) be poured through the
KleanShield¥ drain. Check that water flows out the drain.
FAN
GUARD
KLEANSHIELD¥
Figure 2-6 Inspecting Compartment
Interior Accessories
REMOVABLE
PAN RACKS
Figure 2-4 Inspecting
Compartment drains
OVERFLOW
DRAIN
WATER
LEVEL
SENSOR
ASSEMBLY
RESERVOIR
DRAIN
OPENING
Figure 2-5 Fan Guard Shown in
Installed Position
FAN GUARD
SHOWN PULLED
DOWN TO LOCK IT
IN PLACE
LARGE END OF
KEYHOLE AT
BOTTOM
Figure 2-3 KleanShield¥
Installation
FIT UP OF
KLEANSHIELD¥
PIPE