HIGH ALTITUDE SPECIFICATIONS
Rating Plate
*MANIFOLD PRESSURE NATURAL GAS=3.5 INWC
**MANIFOLD PRESSURE L.P. GAS=10.5 INWC
For- CANADA
HIGH ALTITUDE SPECIFICATIONS
Rating Plate
*MANIFOLD PRESSURE NATURAL GAS=3.5 INWC
**MANIFOLD PRESSURE L.P. GAS=10.5 INWC
6
54,000
72,000
108,000
High Fire
3
4
Qty
High Fire Low Fire Orifice
Qty
Low Fire Orifice
0-2000 54000 51300 35100 33350 1.95mm 1.20mm
2000-3000 47520 45144 30888 29344 1.90mm 1.15mm
54,000 3000-4000 45360 43092 29484 28010 1.90mm 1.10mm 3
4000-5000 43200 41040 28080 26676 1.85mm 1.10mm
5000-6000 41040 38988 26676 25342 1.85mm 1.10mm
0-2000 72000 68400 46800 44460 1.95mm 1.20mm
2000-3000 63360 60192 41184 39125 1.90mm 1.15mm
72,000 3000-4000 60480 57456 39312 37346 1.90mm 1.10mm 4
4000-5000 57600 54720 37440 35568 1.85mm 1.10mm
5000-6000 54720 51984 35568 33790 1.85mm 1.10mm
0-2000 90000 85500 58500 55600 1.95mm 1.20mm
2000-3000 79200 75240 51480 48906 1.90mm 1.15mm
90,000 3000-4000 75600 71820 49140 46683 1.90mm 1.10mm 5
4000-5000 72000 68400 46800 44460 1.85mm 1.10mm
5000-6000 68400 64980 44460 42237 1.85mm 1.10mm
0-2000 108000 102600 70200 66690 1.95mm 1.20mm
2000-3000 95040 90288 61776 58687 1.90mm 1.15mm
108,000 3000-4000 90720 86184 58968 56020 1.90mm 1.10mm 6
4000-5000 86400 82080 56160 53352 1.85mm 1.10mm
5000-6000 82080 77976 53352 50684 1.85mm 1.10mm
0-2000 54000 51300 35100 33350 1.95mm 1.20mm
2001-4500 48600 46170 31590 30011 1.90mm 1.15mm
0-2000 72000 68400 46800 44460 1.95mm 1.20mm
2001-4500 64800 61560 42120 40014 1.90mm 1.15mm
90,000 5
2001-4500 81000 76950 52650 50018 1.90mm 1.15mm
0-2000 108000 102600 70200 66690 1.95mm 1.20mm
2001-4500 97200 92340 63180 60021 1.90mm 1.15mm
0-2000 90000 85500 58500 55560 1.95mm 1.20mm
30
(BTU/hr)
(mm)* (mm)**
Input BTU/hr Altitude(ft) Input Output Input Output Natural Gas LP Gas
(BTU/hr)
(BTU/hr)
(BTU/hr)
(mm)* (mm)**
(BTU/hr)
(BTU/hr)
(BTU/hr)
(BTU/hr)
Input BTU/hr Altitude(ft) Input Output Input Output Natural Gas LP Gas