Model EEG-141, 142, 143, 144
3-15. CHANGING THE FILTER
PAD
In order to assure good oil pumping performance, the filter pad (or
paper) should be changed at least once per day.
If the filter pad has not been changed, a reminder shows on the
display, “CHANGE PAD”. Press
√√
√√
√ button to cancel the
message, but it reappears every 4 minutes until the filter pad has
been changed.
1. Make sure the main power switch is in the ON position.
2. Open the door, lift-up on the drain pan stop and pull-out the
drain pan assembly, using the handle on the drain pan.
Figures 1 & 2.
This pan could be hot! Use protective cloth or glove,
or severe burns could result.
If the filter pan is moved while full of oil, use care to
prevent splashing, or burns could result.
3. Lift the pan cover from the drain pan. Figure 3.
4. Lift the crumb basket from the drain pan. Wipe the oil and
crumbs from the crumb basket. Clean the crumb basket with
soap and water, then thoroughly rinse with hot water.
Figure 4.
Figure 1
Figure 2
Figure 3
Figure 4
3-17 609