Henny Penny EEG-141 Fryer User Manual


 
Model EEG-141, 142, 143, 144
7-2. ERROR CODES In the event of a control system failure, the digital display shows an
error message. The message codes are shown in the DISPLAY
column below. A constant tone is heard when an error code is
displayed, and to silence this tone, press any button.
DISPLAY CAUSE CORRECTION
“E-4” Control board • Turn switch to OFF position, then turn switch back to ON;
overheating if display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstructions
“E-5” Oil overheating • Turn switch to OFF position, then turn switch back to ON;
if display shows “E-5”, the heating circuits and temperature
probe should be checked
“E-6A” • Temperature • Turn switch to OFF position, then turn switch back to ON;
probe open if display shows “E-6A”, the temperature probe should be
checked
“E-6B” • Temperature • Turn switch to OFF position, then turn switch back to ON;
probe shorted if display shows “E-6B”, the temperature probe should be
checked
“E-10” High limit Press the red reset button under the right side of the controls;
if high limit does not reset, high limit must be replaced
“E-15” Drain switch Make sure drain knob is completely pushed-in; if E-15 persists,
have drain switch checked
“E-18-A” • Left level sensor open • Turn switch to OFF position, then turn switch back to ON; if
“E-18-B” • Right level sensor open display still indicates a failed sensor, have the connectors
“E-18-C” • Both level sensors open checked at the control board; have sensor checked & replace if
necessory
809 7-3