Model EEG-141, 142, 143, 144
7-2. ERROR CODES
“E-20-A” • Pressure Switch • If fan is not running, have pressure switch checked; should be
“FAN SENSOR failure open circuit if no air pressure
STUCK • wiring problem • If fan is running, wiring error, or relay on I/O board closed
CLOSED” • I/O board failure
“E-20-B” • Pressure Switch • Press power button to vat off and back on again, if E-20-B
“NO DRAFT” failure/hose loose persists, have pressure switch checked; should be open circuit
“CHECK • Draft Fan failure/ if no air pressure; make sure hose is connected to fan and
FAN” low voltage pressure switch
• Flue or hood • Have draft fan checked; low voltage going to fan
obstructions • check the fryer flue and hood system for obstructions
“E-20-D” • Failure to ignite/ • Press power button to vat off and back on again, if E-20-D
“IGNITION” no flame sense persists, check gas line connections; check gas shut-off valve;
“FAILURE” have ignition module checked; gas valve checked; flame sensor
gap checked; gas valve and ignition module wiring checked
“E-21” • Slow heat recovery • Have a certified service technician check the fryer for correct
voltage to the unit; have heat circuit checked; have unit
checked for loose or burnt wire
“E-22”‘NO • Burner not igniting • Have gas valve and heat circuit checked
HEAT” “CHECK
GAS VALVE”
“E-41”, “E-46” • Programming • Press power button to vat off and back on again, if any
failure of the error codes, have the controls re-initialized; if error code
persists, have the control board replaced
“E-47” • Analog converter • Press power button to vat off and back on again, if “E-47”
chip or 12 volt persists, have the I/O board, or the PC board replaced; if
supply failure speaker tones are quiet, probably I/O board failure; have the
I/O boardreplaced
“E-48” • Input system error • Have PC board replaced
“E-54C” • Temperature input • Turn switch to OFF, then back to ON; have control PC board
error replaced if “E-54C” persists
“E-60” • AIF PC board not • Press power button to vat off and back on again if “E-60”
communicating with persists, have the connector between the PC boards checked;
control PC board replace AIF PC board or control PC board if necessary