Henny Penny EEG-141 Fryer User Manual


 
Model EEG-141, 142, 143, 144
Filter Tracking Mode (SP-8)
Filter Tracking signals the operator when the oil needs filtering by
counting the number Cook Cycles between filters
Press button and “SP-8” and “FILTER TRACKING
MODE” show in the display. Use the and
buttons to choose either “1.MIXED” filter tracking or
“2.GLOBAL”.
GLOBAL means all the products have the same number of
cook cycles between filters.
MIXED means each product may be set with different number
of cook cycles between filters. The controls adds the
cycle counts (see example at left) and when the counts equal 1
or greater, filtering is suggested. Ex: 1 load of fish, 2 loads of
french fries, a load of chicken equals 1. 1/2 + 1/8+1/8+1/4=1.
MIXED
If MIXED is selected, press button and “SP-8A” and
“SUGGEST FILTER AT …” shows in the left display, and a
value between 75% and 100% shows on the right display.
Press the and buttons to change this value.
The lower the value, the sooner the control recommends to
filter. Ex: If set to 75%, the control suggest filtering after 3/4 of
the programmed cook cycles is met, whereas at 100%, all the
cook cycles must be completed before the control suggest
filtering.
Press and “SP-8B” and “LOCKOUT ENABLED?”
shows in the left display. Press the and buttons to
choose YES or NO.
If set to YES, when the controls suggest filtering, “FILTER
LOCKOUT”/”YOU *MUST* FILTER NOW”, shows in the
display, and it refuses further cook cycles until the vat is filtered.
Press and “SP-8C” and “LOCKOUT AT...” shows in the
left display and a value between 100% and 250% shows on the
right display. Press the and buttons to change this
value. The lower the value, the sooner the “lockout” occurs.
Ex: If set at 100%, “lockout” occurs when the cycle counts
reaches 1 or greater. Set at 200%, twice as many cycles are
counted before “lockout” occurs. See example above.
6-1. SPECIAL PROGRAM
MODE (Continued)
6-4 909
No. Cook Cycle
Product Cycles Count
Fish 2 1/2
French Fries 8 1/8
Chicken 4 1/4