Hobart OV500E1 ML- 132501 Double Oven User Manual


 
OV500 SERIES RACK OVEN - REMOVAL AND REPLACEMENT OF PARTS
14. Remove heat slinger and mounting bracket
from motor.
15. Reverse the procedure to install.
GAS VALVE
A. CHECK ALL JOINTS PRIOR TO THE
GAS VALVE (SOLENOID) BEFORE
LIGHTING UNIT.
B. CHECK ALL JOINTS AFTER TO THE
GAS VALVE (SOLENOID) AFTER THE
UNIT IS LIT.
1. Open control compartment door to gain access
to gas manifold assembly.
2. Disconnect the gas supply union fitting from gas
manifold assembly.
NOTE: The burner mounts may have to be loosened
to allow the gas valve to rotate.
3. Remove the valve from the burner manifold.
4. Reverse procedure to install.
5. Check GAS PRESSURE as outlined under
SERVICE PROCEDURES AND
ADJUSTMENTS.
6. Operate oven and check for proper operation.
GAS MANIFOLD / ORIFICES
A. CHECK ALL JOINTS PRIOR TO THE
GAS VALVE (SOLENOID) BEFORE
LIGHTING UNIT.
B. CHECK ALL JOINTS AFTER TO THE
GAS VALVE (SOLENOID) AFTER THE
UNIT IS LIT.
1. Open control compartment door to gain access
to gas manifold assembly.
2. Disconnect lead wires to gas valve, ignitor and
flame sensor.
3. Loosen the gas supply union fitting from gas
manifold assembly.
F25361 (January 2010) Page 18 of 60