OV500 SERIES RACK OVEN - REMOVAL AND REPLACEMENT OF PARTS
3. Disconnect lead wires from vent motor and vent
switch.
4. Loosen vent cam set screw and remove cam
from shaft.
NOTE: Mark location of cam on vent motor shaft.
NOTE: When installing, position cam on motor shaft
to prevent rubbing.
5. Remove screws securing vent motor from vent
motor bracket.
6. Reverse the procedure to install.
OVEN CAVITY VENT SWITCH
1. Remove screws securing vent motor cover from
vent motor box.
2. Disconnect lead wires from vent switch.
3. Remove screws securing vent switch from vent
bracket.
4. Reverse procedure to install.
THERMOSTAT (BACK UP
SYSTEM ONLY)
1. Open control compartment door to gain access
to backup thermostat.
2. Remove component panel cover.
3. Remove screws securing back up system panel
from control box.
4. Disconnect lead wires from backup thermostat.
5. Remove screws securing thermostat from
backup system panel.
F25361 (January 2010)Page 25 of 60