Hobart OV500E1 ML- 132501 Double Oven User Manual


 
OV500 SERIES RACK OVEN - REMOVAL AND REPLACEMENT OF PARTS
2. Remove controller rear cover.
3. Disconnect all control harness connections.
NOTE: Ovens with Kosher operation will have a
connector for the key lock switch to be disconnected.
4. Remove nuts and washers securing controller
to controller panel.
NOTE: When installing ensure stand off spacers are
installed behind controller board.
5. Reverse the procedure to install.
6. Verify controller default settings.
7. Check oven for proper operation.
HIGH LIMIT SWITCH
NOTE: On OV500G1 & OV500G2 oven, access high
limit switch at top of oven in service entrance box.
On OV500E1 & OV500E2 oven, access high limit
switch at the bottom of the control component box.
1. Open control compartment door and remove
component box cover.
2. Disconnect high limit switch lead wires.
3. Remove screws securing high limit switch to
component box or service entrance box.
4. Access high limit probe at top of oven.
5. Remove screws securing probe cover.
6. Remove high limit probe fitting from oven and
pull high limit out.
F25361 (January 2010) Page 22 of 60