Lincoln Electric SVM100-A Appliance Trim Kit User Manual


 
SQUARE WAVE TIG 255
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-35
TROUBLESHOOTING & REPAIR
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
DC TIG MODE
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
• Perform all voltage and waveform checks with high frequency circuit OFF.
_____________________________________________________________________
0 volts
20 volts
2ms
CH1
This is a typical DC (+) output voltage wave-
form generated from a properly operating
machine. Note that each vertical division
represents 20 volts and that each horizontal
division represents 2 milliseconds in time.
The machine was loaded with a resistance
grid bank. The TIG 255 display read 200
amps at 50VDC.
Note: Scope probes connected at machine
output studs: (+) probe to electrode, (–)
probe to work.
MACHINE LOADED TO 200 AMPS AT 50 VDC
Volts/Div................................20 V/Div.
Horizontal Sweep .................2 ms/Div.
Coupling.........................................DC
Trigger.....................................Internal
SCOPE SETTINGS