Lincoln Electric SVM100-A Appliance Trim Kit User Manual


 
A-2
INSTALLATION
SQUARE WAVE TIG 255
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Read entire installation section before starting
installation.
SAFETY PRECAUTIONS
SELECT SUITABLE LOCATION
Place the welder where clean cooling air can freely
circulate in through the rear louvers and out through
the side louvers. Dirt, dust or any foreign material that
can be drawn into the welder should be kept at a
minimum. Failure to observe these precautions can
result in excessive operating temperatures and
nuisance shut-downs. Square Wave TIG 255 power
sources carry an IP23 enclosure rating. They are
rated for use in damp, dirty environments subject to
occasional falling water such as rain.
STACKING
Square Wave TIG 255’s cannot be stacked.
TILTING
Each machine must be placed on a secure, level
surface, either directly or on a recommended
undercarriage. The machine may topple over if this
procedure is not followed.
ELECTRIC SHOCK can kill.
Only qualified personnel should
perform this installation.
Turn the input power OFF at the
disconnect switch or fuse box
before working on this
equipment.
Do not touch electrically hot
parts.
Always connect the Square Wave
TIG 255 grounding terminal
(located on the bottom of the
input connection box) to a good
electrical earth ground.
HIGH FREQUENCY INTERFERENCE
PROTECTION
The spark gap oscillator in the high frequency genera-
tor, being similar to a radio transmitter, can be blamed
for many radio, TV and electronic equipment interfer-
ence problems. These problems may be the result of
radiated interference. Proper grounding methods can
reduce or eliminate radiated interference.
Radiated interference can develop in the following
four ways:
1. Direct interference radiated from the welder.
2. Direct interference radiated from the welding leads.
3. Direct interference radiated from feedback into the
power lines.
4. Interference from re-radiation of “pickup” by un-
grounded metallic objects.
Keeping these contributing factors in mind, installing
equipment per the following instructions should
minimize problems.
1. Keep the welder power supply lines as short as
possible and completely enclose them in rigid
metallic conduit or equivalent shielding for a
minimum distance of 50 feet (15.2m). There
should be good electrical contact between this
conduit and the welder. Both ends of the conduit
should be connected to a driven ground and the
entire length should be continuous.
2. Keep the work and electrode leads as short as
possible and as close together as possible.
Lengths should not exceed 25 ft (7.6m). Tape the
leads together when practical.
3. Be sure the torch and work cable rubber coverings
are free of cuts and cracks that allow high
frequency leakage. Cables with high natural
rubber content, such as Lincoln Stable-Arc® better
resist high frequency leakage than neoprene and
other synthetic rubber insulated cables.
WARNING