Lincoln Electric SVM100-A Appliance Trim Kit User Manual


 
SQUARE WAVE TIG 255
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-36
TROUBLESHOOTING & REPAIR
0 volts
20 volts
2ms
CH1
AC TIG MODE (AUTO - BALANCE ON)
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
• Perform all voltage and waveform checks with high frequency circuit OFF.
_____________________________________________________________________
0 volts
20 volts
2ms
CH1
These are typical AC output voltage wave-
forms generated from a properly operating
machine. Note each vertical division repre-
sents 20 volts and each horizontal division
represents 2 milliseconds in time. The
machine was loaded with a resistance grid
bank. As the load is increased the output
waveform becomes more “square”.
Note: Scope probes connected at machine
output studs: (+) probe to electrode, (–)
probe to work.
MACHINE LOADED TO 50 AMPS AT 26VAC MACHINE LOADED TO 200 AMPS AT 46 VAC
Volts/Div................................20 V/Div.
Horizontal Sweep .................2 ms/Div.
Coupling.........................................DC
Trigger.....................................Internal
SCOPE SETTINGS