Taylor 632 Freezer User Manual


 
21
Model 632 Operat ing Procedu res
081117
Rotate th e draw valve bracket to the left and cent er it
into position by raising the draw arm and placing it into
the slotted g roove of the draw valve b racket.
Note: The draw valve bracket must be positioned with
the notch to the left.
Figure 27
Step 5
Lay the air tube in the bottom o f the mix hopper.
Step 6
Slide the rear drip pan(s) into the hole inthe s idepanel.
Figure 28
Step 7
Install the dr ip tray and splash shield.
Sanitizing
Step 1
Preparea pailof approved 100PP Msanitizing s olution
(examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R or 2 gal.
[7.6 liters] of Stera- SheenR). USE WARM WATER
AND FOLLO W THE MANUFACTURER’S
SPECIFICATIONS.
Step 2
Pour the sanitizing solution into the hopper and allow
it to flow into the freezing cylinder.
Figure 29
Step 3
While the solution is flowing into the freezing cylinder ,
brush clean the mix hopper. While cleaning the mix
hopper, take particular care in brushing the mix level
sensing p robe on the rear wall of the hopper, the mix
inlet hole, and the air tubes.
Figure 30