Model 632 To the Installer
130924
S Stationary appliances which are not equipped
with a power c ord and aplug or another device
to disconnect the appliance from the power
source must have an all-pole disconnecting
device with a contact gap of at least 3 mm
installed in the external installation.
S Appliances that are permanently connected to
fixed wiring and for which leakage currents
may exceed 10 mA, particularly when
disconnect ed, not used for l ong periods, o r
during initial inst allation, shall have protectiv e
devices such as a GFI to protect against the
leakage of current, installed by authorized
personnel to the local codes.
S Supply cords used with this unit shall be
oil-resistant , sheathed flexible cable not
lighter than ordinary poly chloroprene or other
equivalent synthet ic elastomer-sheathedcord
(Code designation 60245 IE C 57) installed
with the proper cord anchorage to relieve
conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
If the supply cord is dam aged, it must be
replaced by an author ized Taylor service
technician in order to avoid a hazard.
Beater Rotation
Beater rota tion must be clockwise as viewed
looking into the freezing cylinder.
Note: The following procedures must be
perfo rmed by an auth orized Taylor service
techn ician.
To correct the rotat ion on a three- phase unit,
interchange any two incoming power supply lines at
freezer main terminal block only. To correct rotation on
a single- phase unit, change the leads inside the
beater motor. (Follow the diagram printed on the
motor.)
Electr ical connections are made directly to the
terminal block provided in the maincont rol box located
behind the service panel.
Refriger ant
In consideration of our environment, Taylor
proudly uses only eart h friendly HFC refrigerants. The
HFC ref rigerant used in this unit is R404A. This
refrigerant is generally cons idered non-toxic and
non-flammable, with an Ozone Depleting Potential
(ODP) of z ero (0).
However , any gas under pres sure is potentially
hazardous and must be handled with caution. NEVER
fill any refriger ant cylinder completely with liquid.
Filling the cy linder to approximately 80% will allow for
normal expansion.
Use only R404A refriger ant that conforms to
the AHRI standard 700 specification. The use of any
other refr igerant may expose users and operat ors to
unexpected safety hazards.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant bur ns should occur, flush
immediately with cold water. If burns are severe, apply
ice packs and contact a physician immediately.
Taylor reminds technicians to be cautious of
government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
fact ory Serv ice Department.
W ARNING: R404A refrigerant used in
conjunction with polyolester oils is extremely moisture
absorbent. When opening a r efrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the o il.