Taylor 632 Freezer User Manual


 
26
Important: Operator Checklist
Model 632
081117
Section 7 Important: Operator Checklist
During Cleaning and Sanitizing
ALWAYS FOLLOW L OCAL HEALTH CODES.
Cleaning a nd sanitizin g schedules are governed
by federal, state, or local regulatory agencies,
and must be followed accordingly. If the unit
has a “Standby mode”, it must not be used in
lieu of proper cleaning and sanitizing
procedures and frequencies set forth by the
ruling health authority. The following check
points should be stressed during the cleaning
and sanitizing operations.
CLEANING AND SANITIZING MUST BE
PERFORMED DAILY.
Cleaning and sanitizing sc hedules are governed by
your St ate or local regulatory agencies and must be
followed accordingly. The following check points
should be stressed during the cleaning and sanitizing
operations.
Troubleshooting Bacterial Count
j 1. Thoroughly clean and saniti ze machine
regularly, including c omplete disassembly and
brush cleaning.
j 2. Use all brushes supplied for thorough cleaning.
The brushes are specially designed to reach all
mix passageways.
j 3. Use the white bristle brush to clean the mix inlet
hole which extends from the mix hopper down
to the rear of the freezing c ylinder.
j 4. Use the black bristle brus h to thoroughly clean
the rear shell bearing located at the rear of the
freezing cylinder. Be sure to have a generous
amount of cleaning solution on the brush.
j 5. IF LO CAL HEALTH CODES PERMIT THE
USE OF RERUN, make sure the mix rerun is
stored in a sanitized, covered stainless steel
container and used the following day. DO NOT
prime the machine with rerun. When using
rerun, skim off th e foam and discard. Mix the
rerun withfr esh mix in a ratio of 50/50 during the
days operation.
j 6. On a designatedday of the w eek, run the mix as
low as feasible and discard it after closing. This
will break the rerun cycle and reduce the
possibility of high bact eria and coliform counts .
j 7. Properly prepare the cleaning and sanitizing
solutions. Read and follow label directions
carefully. Too strong of a solution may damage
the parts and too weak of a solution will not do
an adequate job of cleaning or sanitizing.
j 8. The tem perature of the mix in the mix hopper
and walk- in cooler should be below 40_F.
(4.4_C.).
Regular Maintenance Checks
j 1. Replace scraper blades that are nicked or
damaged. Before installing the beater
assembly, be certain that scraper blades are
properly attached to the helix or pins.
j 2. Check the rear shell bearing for signs of wear
(excessive mix leakage in rear drip pan) and be
certain it is properly cleaned.
j 3. Using a scr ewdriver and cloth towel, keep th e
rear shell bearing and the female drive socket
clean and free of lubricant and mix deposits.
j 4. Dispose of o- rings and seals if they are worn,
torn, or fit too loosely, and replace with new
ones.
j 5. Follow all lubricating procedures as outlined in
“Assembly”.
j 6. If your machine is air cooled, check the
condensers for accumulation of dirt and lint.
Dirty condensers will reduce the ef ficiency and
capacity of the machine. Condensers s hould be
cleaned monthly with a soft brush. Never use
screwdrivers or other metal probes to c lean
between the fins.
Note: For machines equipped with an air filt er,
it will be neces sary to vacuum clean the filters
on a monthly schedule.