27
Model 632 Important: Operator Checklist
081117
CAUTION: Always disconnect
electri cal power prior to cleaning th e
condenser. Failure to follow this instruction
may result in electrocution.
j 7. If your machine is equipped with an auxiliary
refrigeration system, check the auxiliary
condenser for accumulation of dirtand lint. Dirty
condensers will reduce the refrigeration
capacity of the mix hopper. Condensers must
be cleaned monthly with a soft brush. Never
use screwdrivers or other metal probes toclean
between the fins.
CAUTION: Always disconnect
electri cal power prior to cleaning the
condenser. Failure to follow thisinstruction
may result in electrocution.
j 8. If your machine is water cooled, check thewater
lines for kinks or leaks. Kinks can occur when
the machine is m oved back and forth for
cleaning or maintenance purposes.
Deteriorated or cr acked water lines should be
replaced only by an authorized Taylor
distributor.
Winter Storage
If the place of bus iness is tobe closed during the winter
months, it is important to prot ect the freezer by
following certain precautions, particularly if the
building is subject to fr eezing conditions.
Disconnect the freezer from the main power source to
prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Relieve pressure on the spring in the water
valve. Use air pressure on the outlet side to blow out
any wate r remaining in the condenser. This is
extremely important. Failure to follow this procedure
may cause severe and costly damage to the
refrigeration system.
Your local Taylor Distributor can perform this winter
storage service for you.
Wrap detac hable parts of the freezer such as beater,
blades, drive shaf t, and freezer door, and place them
in aprotecteddry place. Rubber trim parts andgaskets
can be protected by wrapping them with
moisture- p roof paper. All parts should be thoroughly
cleaned of dried mix or lubrication which attract mice
and other vermin.