To the Installer
Model 632
110407
Air Cooled Units
DO NOT obs truct air intake and discharge openings:
Air cooled units require a minimum of 3” (76 mm) of
clearance around all sides of the freezer to allow for
adequate a ir flow acr oss the condensers. A deflector
is provided to prevent recirculation of warm air. Failure
to allow adequate clearance can reduce the
refrigeration capacity of the freezer and possibly
cause permanent damage to the compressor.
Water Connections
(Water Cooled Units On ly)
An adequate cold water supply must be provided with
a hand shut- off valve. On the underside rear of the
base pan, two 1/2” I.P.S. water connect ions for inlet
and outlet have been provided for easy hook- up. 1/2”
inside diameter water lines should be connected tothe
machine. (Flexible lines are recommended, if local
codes permit.) Depending on local water conditions, it
may be advisable to install a water st rainer to prev ent
foreign substances from clogging the automatic water
valve. There will be only one water “in” and one water
“out” connection for both single- head and
double- head units. DO NOT install a hand shut- off
valve on the water “out” line! W ater should always flow
in this order: first, through the automatic water valve;
second, through the condenser; and third, through the
outlet fitti ng to an opentrapdrain.
A back flow preventi on device is required
on the incoming water connection side. P lease
refer to the applicable National, State, and local codes
for determining the proper configuration.
Electri cal Connections
In the United States, this equipment is intended to be
installed in accordance with the National Electr ical
Code (NEC), ANSI/NFPA 70-1987. The purpose of the
NEC code is the practic al safeguarding of persons and
property from hazards arising fr om the use of
electric ity. This code contains provisions considered
necessary for safety. In all other areas of the world,
equipment should be i nstalled in accordance with the
existing local codes. Please contact your local
authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each unit requir es one power supply for each data
label on the unit. Check the data l abel(s) on the freezer
for branch circuit overcurrent prot ection or fuse, circuit
ampacity and other electrical specific ations. Refer to
the wiring d iagram pr ovided ins ideof the electrical box,
for proper power connections.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment’s fr ame.