Error codes for Gaggenau Steam Oven model ED-220/221
Error Code Cause Example Corrective Action
F30
EEPROM not programmable
F61
Too much water or not enough
heat during calibration run
Will not go into
diagnostic mode will
not complete
calibration and will
cancel
Replace the display board. See note 4 open heating
element
F62
Not enough water or too much
heat during calibration run
Steam dispensing
clogged, or
convection fan
stalling
F63
F70
F71
Oven does not cool at end of
calibration. Water in base pan
of oven drain pump is running
for more than two minutes
Condensation cooling
valve inoperative.
Leaking from drain or
internal hoses
blocked drain, drain
running uphill, drain
coiled.
Check convection fan for proper operation,
replace if necessary. Replace steam valve
assembly. Rerun calibration check cooling
valve, replace water valve if necessary correct
leak, dry off the sensors on rely board. Correct
drain restriction