Thermador PDR48 Range User Manual


 
B
WFK 2401 Washer Fault Codes
Fault
Code
Faults Possible Causes/Notes Corrective Actions
09 NTC failed
NTC open circuited.
NOTE: Fault code occurs during test program.
Disconnect NTC and measure resistance at terminals (~5.4 – 6.5 k @
20°C (68°F)). Replace NTC if faulty.
10 NTC failed
NTC shorted
NOTE:
Fault code occurs during test program.
Disconnect NTC and measure resistance at terminals (~5.4 – 6.5 k @
20°C (68°F)). Replace NTC if faulty.
12 Drum motor
reversing
relays failed
Reversing relays have failed.
NOTE:
Fault code occurs during test program.
Check voltage at motor connectors when motor is energized. If voltage
doesn’t reverse, replace faulty control module.
NOTES:
While running water inlet valves, pressure switch, heater & drain pump test, display shows fault codes 01 since water doesn’t totally fill & 02
since water isn’t heated. This is normal.