Thermador PDR48 Range User Manual


 
B
WTMC Service Tips - - Test program (4B): Fault Codes
WTMC Dryer Test Program Fault Codes
Fault
Code
Fault Solution Notes Effect
E:23
Model variant doesn’t
match table
Replace faulty control module. Dryer stops &
can’t be
restarted.
E:24
Software version
doesn’t match table
Replace faulty control module. Dryer stops &
can’t be
restarted.
E:25
Damaged data table Replace faulty control module. Dryer stops &
can’t be
restarted.
E:26
Control error Replace faulty control module. Dryer stops &
can’t be
restarted.
NOTE: Fault displayed alternates with # of times fault occurred every
two (2) seconds. If there’s no faults, displays will be blank.
E:xx = fault code from E11 – E39 (e.g. E:11)
C:xx = # of occurrences (e.g. C:01)
NOTE: When test program is initially entered,
last fault code will show. Display will be cleared
once an
y
test is started.