Thermador PDR48 Range User Manual


 
GAGGENAU Steamer VK 230
27
F 6 Steam sensor faulty installed (only possible during
factory or universal comparison!)
8 FUNCTION CODES
Faults at the appliance, a correct or incorrect adjustment as well
as the RESET-function are indicated / confirmed by signals or
error codes.
FAC Factory comparison is running
dEF Universal comparison is running
Blinking heat up symbol
Customer Comparison in use
Explanations:
Blinking in the display
Holyday safety function/after 4 h continuously
running Reset: switch off/on appliance
OOO Factory- / universal comparison successfully finished
F Error during the RESET (internal self test)
F 1 Error when starting an adjustment, e.g. appliance
has not yet been adjusted by a factory or universal
comparison
Drain symbol
Drain valve did not reach end position
Or
After starting the adjustment, the position „steaming“
has not been chosen within 8 sec.
Drain symbol
Drain valve open
Or
After an adjustment another adjustment is started
Limiter symbol
Dry run or overheating / above 107 °C/225°F
F 2 Fault at the water sensor
F 3 Fault at the steam sensor
If appliance will be switched off and on F 2 occurs in
the display=Appliance /Sensor too hot.
F 4 Fault at the TRIAC or heating element or the water
temperature has not increased for min 50°K/90°F
Reset: Switch off appliance to cool down
F 5 Water sensor not in right position (Function code
shown only possible during factory or universal
comparison!)
Display compl. Switched ON and sounding signal
Reset confirmation/Display and Buzzer check
Comparison now required
Blinking „o“
Child lock function in use