Thermador PDR48 Range User Manual


 
Thermador®
Gaggenau EB 270/271/290/291 Oven Error Codes...continued
Note 1 Oven sensors should measure 1050 ohms at
75 degrees F. if the sensor measures
correctly (within 10%), check each leg of the
sensor to ground and to each phase of the
electrical supply. If all checks OK, check the
contacts inside the molex plug. If the spring
contacts are bent or crushed, the sensor will
create intermittent errors.
Note 2 Meat probe is an NTC device and will
measure approximately 50,000 ohms at room
temperature. Resistance decreases as
temperature increases.
Note 3 Catalyst sensor checks much the same as
oven sensor. However, the resistance will be
500 ohms at room temperature.
Note 4 This oven has a very comprehensive
diagnostic program. Please refer to
Gaggenau 2000 service Manual for specific
instructions.
Note 5 The program is located in the display head on
this oven. If the clock/display is replaced, the
parameters must be programmed into the
new board. Please refer to the Gaggenau
2000 Service Manual for instructions.
26