Thermador PDR48 Range User Manual


 
B
WFMC Service Tips – Test Program (2B): Module Fault Codes (Test1)
Test P1:ERRORS / P:01 (Viewing control module fault codes)Start & end test P1
(WFMC6400) / (P:01) (WFMC3200) by pushing Start/Pause button. Scroll through list of fault codes
by pushing Spin Selection (WFMC3200) or Menu (WFMC6400) buttons.
WFMC3200 display alternates between fault code (e.g. E:01) & when fault occurred on in last 8
washes (e.g. : C:00) – shows C:00 if fault didn’t occur.
WFMC6400 display shows fault code & when fault occurred on in last 8 washes (e.g. 0 – Er:01)
WFMC32
Display
WFMC64
Display
Test # Problem Possible Cause(s)
E:01 Er:01 washing
Door open Door lock not engaged
E:02 Er:02 washing
Door lock doesn’t unlock Jammed lock or bad wire harness
E:03 Er:03 washing
Door lock doesn’t lock Jammed lock or bad wire harness
E:04 Er:04 washing
Door control broken Faulty Triac or control module
E:05 Er:05 P:16
NTC open-circuited Faulty NTC or bad wire harness
E:06 Er:06
P:16
NTC shorted Faulty NTC or bad wire harness
E:07 Er:07 P:16
Unpexpected heating (heater on at wrong time) Faulty heater or stuck heater relay
E:08 Er:08 P:16
Heater doesn’t shut off Faulty heater or stuck heater relay
E:09 Er:09 P:4
Communication lost to motor Faulty wire harness
---- Er:10
P:11
Flow meter gives wrong values Faulty flow meter or wire harness
----
Er:11
P:8/9/13
No water flow (within 6 minutes) Faulty inlet valve, wire harness, hose
E:12 Er:12 P:8/9/13
Water supply time exceeded Faulty inlet valve, wire harness, hose
E:13 Er:13 P:15
Drian pump time exceeded Faulty drain pump, wire harness, hose
E:14 Er:14 P:9
Overflow level exceeded Faulty/blocked pump, hose, inlet valve
---- Er:15
P:8
Pressure sensor gives failure voltage level Faulty pressure sensor, wire harness
----
Er:16
P:8
Can’t calibrate pressure sensor Faulty pressure sensor, wire harness
E:20 Er:20 P:4
Spinning aborted due to unbalanced load Unbalanced load or faulty wire harness
E:21 Er:21
Excessive foam Wrong or too much detergent used
E:22 Er:22 washing
Frequency synchronization failed Faulty control module
E:24 Er:24 P:4
Motor power relay failed Faulty control module
Last 8 fault codes are
stored & dis
p
la
y
!
HINT: # of faults reads “0
for faults which didn’t occur.
Look at # of faults, not error
#, to see if faults occurred –
scroll thru all faults to check
if any occurred.