Bunn FMD-1 FMD-2 Coffeemaker User Manual


 
11
TROUBLESHOOTING (cont.)
PROBLEM
Product overflows container
Weak product
PROBABLE CAUSE
1. Dispense Switch
2. Dispense Solenoid Valve
1. Water Temperature
2. Whipper Motor
3. Frother
4. Dispense Solenoid Valve
5. Auger Drive - FMD-1
Auger Drive - FMD-2
6. Auger Spring - FMD-1
Auger Spring - FMD-2
7. Auger Motor - FMD-1
Auger Motor - FMD-2
8. Rinse/Run Switch - FMD-1
Rinse/Run Switch - FMD-2
9. Rinse Timer - FMD-2
REMEDY
Refer to
Service -
Dispense Switch
for testing procedures. See page 22
Remove the solenoid valve and clear
any obstructions. Rebuild or replace
the valve if necessary. See page 35
Place an empty container beneath
the dispense tip. Initiate a dispense
cycle and check the water tempera-
ture immediately below the dispense
tip with a thermometer.
Reading for mechanical thermostat
models should be 180°F to 200°F
(see thermostat temperature settings
decal in
USER NOTICES
on page 3.)
Refer to
Service
- Whipper Motor for
testing procedure. See page 25
Refer to
Service
- Frother Compo-
nents. See page 25
Refer to
Service
- Dispense Solenoid
Valve for test procedures. See page
35
Refer to
Service
- Auger Drive Com-
ponents. See page 13
See page 15
Refer to
Service
- Auger Drive Com-
ponents. See page 13
See page 15
Refer to
Service
- Auger Drive Com-
ponents. See page 13
See page 15
Refer to
Service -
Rinse/Run Switch
for test procedures. See page 31
See page 33
Refer to
Operation
- Rinse Timer.
See Page 5
29112 101598