Bunn FMD-1 FMD-2 Coffeemaker User Manual


 
9
TROUBLESHOOTING (cont.)
PROBLEM
Product will not dispense (cont.)
Water is not hot
PROBABLE CAUSE
5. Solenoid Valve (Inlet)
6. A) Level Control Board and Probe
- FMD-1
B) Control Board and Probe - FMD-
2
7. A) Auger Drive - FMD-1
B) Auger Drive - FMD-2
8. Water Strainer
9. Lime build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water conditions.
Excessive mineral build-up on stain-
less steel surfaces can initiate corro-
sive reactions resulting in serious
leaks.
10. Transformer - FMD-2
1. Limit Thermostat
CAUTION - Do not eliminate or by-
pass limit thermostat. Use only BOM
replacement part #29329.1000
2. Control Thermostat
3. Tank Heater
REMEDY
Refer to
Service
- Solenoid Valve
(Inlet) for testing procedures. See
page 36
Refer to
Service
- Level Control Board
and Probe for testing procedures.
See page 30
Refer to
Service
- Control Board and
Probe for testing procedures. See
page 20
Refer to
Service
- Auger Drive. See
page 13
Refer to
Service -
Auger Drive. See
Page 15
(A) Direction of flow arrow must be
pointing towards dispenser.
(B) Remove the strainer and check
for obstructions. Clear or replace.
Inspect the tank assembly for exces-
sive lime deposits. Delime as re-
quired.
Refer to
Service
- Transformer for
testing procedures. See page 39
Refer to
Service
- Limit Thermostat
for testing procedures. See page 32
Refer to
Service
- Control Thermo-
stat for testing procedures. See page
19
Refer to
Service
- Tank Heater for
testing procedures. See page 37
29112 051200