Henny Penny CSG Electric Steamer User Manual


 
CSL
CSM
Quick Guide To Programming
(continued)
Setting the clock
•Press the TIMER key (10)
Set clock time (military time) using SELECT arrow keys (16)
•Press and hold TIMER key (10). While TIMER key is pressed,
switch unit off and then back on using ON/OFF key (1).
• Switch unit off again
• Wait (4) seconds, then switch unit back on. Real time is now
stored and displayed.
Setting automatic start-up time
• Press TIMER key (10) until the period in the time display flashes
• Set the desired start-up time (military time) using SELECT arrow keys (16)
• Set cooking mode, temperature, time/probe temperature, and additional
functions as usual, or select a program number
• Enter automatic start-up function by pressing both SELECT arrow keys (16)
simultaneously. When the programmed time is reached, unit will
automatically start up.
Delta-T Cooking
Select PROG (17)
• Select program number using program SELECT arrow keys (21)
• Select any cooking MODE.
• Set desired probe temperature value using the temperature
SELECT arrow keys (16)
• Press SPECIAL FUNCTIONS key (22).
• Press DELTA-T key (27) and enter Delta value using the temperature
SELECT arrow keys (16)
• Save program by pressing PROG key (17)
Programming the CSM Model
To Program
• Begin by turning the mode selector dial (3) to PROG (9)
• Select program number using program SELECT keys (26)
Enter the individual values (mode, temperature, time/probe temperature)
and additional functions desired for each of nine available cooking stages.
IMPORTANTIf you wish to use the same mode in two consecutive intervals
of a program you must reset the mode before programming the next interval.
This is done by quickly turning the mode selector dial (3) away from and
back to the original mode setting without selecting another mode.
• Save program by pressing both program SELECT arrow keys (26) simultaneously
• Turn unit off for 4 seconds. Then turn back on
• To start cooking program, press program START (25) key
NOTE:
• PROG must be selected each time a program is started
• The mode selector dial must be set to OFF for at least 4 seconds prior
to selecting PROG
To change a saved program
• Repeat process to modify the values set
• Press both program SELECT arrow keys (26) to save changes
To lock a program
• Set mode selector dial (3) to PROG (9). Press timer activation key (13).
Set TIMER (15) to “110.” Press Right (DOWN) SELECT arrow key (26).
“NP” will be displayed.
• To unlock, repeat using Left (UP) arrow key. “P” will be displayed.
10
16
22
17
27
3
26
25
9
13
15
21
59