REMOVING THE POWER SUPPLY WIRING TERMINAL
BLOCK AND THE BLOWER MOTOR
1. Disconnect the electrical power to the
oven.
2. Remove the side trim from the oven (see
page 4-2, steps 1 through 4 for the proce-
dure).
NOTE: Before you move the oven from its
mounting location, remove the oven door to
make it easier to move (see page 2-3 for the
procedure).
3. Remove the oven cabinet mounting screws
and pull the oven out of its mounting
location so that you can access the back.
CAUTION: When you work on the built-in
oven, be careful when handling the sheet metal
parts. Sharp edges may be present, and you
can cut yourself if you are not careful.
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
WARNING
Conduit
Clamp
Top Rear Cover
(6 Screws)
4. Remove the screw from the conduit clamp
and remove the clamp.
5. Remove the 6 screws from the top rear
oven cabinet cover.
Cabinet Mounting Screw
(1 Screw On Each Side)
6. To remove the power supply wiring
terminal block:
a) Remove the hex nuts from the wire
terminal studs and remove the wires
from the studs.
b) Remove the two mounting screws from
the terminal block and remove it from
the top of the oven.
Power Supply
Wiring Terminal Block
Wires
Mounting