Taylor H62 & H63 Freezer User Manual


 
19
Models H62 & H63 Important: To the Operator
120126
the MENU/SEL key while under “ENABLE” will accept
the selection and will automatically increase the clock
one hour at 2:00 a.m. on the first Sunday in every April.
It will decrease one hour at 2:00 a.m. on the last
Sunday in every October. Pressing the MENU/SEL
key while under “DISABLE” will accept the selection
and operate normally. Pressing the MENU/SEL key
again will accept the selection and return to the
OPERATOR MENU.
Screen “D” is SYSTEM INFORMATION. The first
screen will indicate the software version used in the
unit.
SOFTWARE VERSION
H63 Control UVC2
Version X.XX
SEL
Press the MENU/SEL key to view the second screen
of the SYSTEM INFORMATION display. This screen
will indicate the version number and number of
language strings.
Language
V1.10r00 English 457
SEL
Press the MENU/SEL key to view the third screen of
the SYSTEM INFORMATION display. This screen will
indicate the Bill of Material number and serial number
for the unit. Press the MENU/SEL key once to return
to the Operator Menu.
B.O.M. 0H6333C000
S/N K0000000
SEL
Screen “E” is AUTO HEAT TIME. This screen is used
to set the time of day in which the heat treatment cycle
will start. Move the cursor under the number you wish
to change. Press the plus key to i ncrease the number;
press the minus key to decrease the number. When
the desired time appears, press the MENU/SEL key
once to return to the OPERATOR MENU.
AUTO HEAT TIME
TIME: 12:00 AM
-- --
<------ ------> +++ ------ SEL
Screen “F” is BRUSH CLEAN CYCLE. This option
allows the manager to select the maximum number of
days between brush cleanings. The brush clean cycle
may only be changed after the freezer has been
manually cleaned, but before it has been placed in the
AUTO or STANDBY mode.
Screen “G” is CURRENT CONDITIONS. This screen
displays the hopper and barrel temperatures. Press
the MENU/SEL key once to view the SERVINGS
COUNTER screen.
HOPPER BARREL
38.5 28.5
TIME C 11:00
The SERVINGS COUNTER screen indicates the
number of draws since the last brush cleaning or since
the last serving counter reset. A maximum of 32,767
draws can be recorded; an additional draw will cause
the counter to restart at zero. Pressing the MENU/SEL
key will return the display to the Operator Menu.
SERVINGS COUNTER
DRAWS
12
SEL
Draws are counted during the AUTO mode of
operation only.