38
Model 8756Troubleshooting Guide
PROBLEM PROBABLE CAUSE REME DY PAGE
REF.
4. Product is too soft. a. Worn scraper blades. a. Replace scraper blades
regularly.
41
b. Dirty condensers or air
filters on a ir cooled units.
b. Clean monthly. 35
c. Inadequate water supply
on water cooled units.
c. Check the water supply.
Check water lines for
leaks or kinks.
1/ 35
d. Inadequate air space
around air cooled units.
d. Allow adequate room for
air flow across the
condensers. Minimum o f
3” (76 mm) clearance on
all sides. Do not obstruct
air discharge on top. 12”
(305 mm) clearance on
top of freezer.
1
e. Viscosity control is set too
warm.
e. Contact a service
technician.
---
5. Mix in the mix cabinet is
too warm.
a. Warm mix was placed in
the tank.
a. Mix added to the mix tank
should be below 40_F
(4.4_C).
34
b. The mix cabinet door was
left open.
b. The door must be kept
closed.
28
c. The mix cabinet door
gasket is not sealing.
c. Repair or replace gasket. ---
d. Dirty mix cabinet
condenser or air filter.
d. Clean monthly. 35
e. The mix cabinet
refrigeration system needs
adjustment.
e. Contact a service
technician.
---
6. Mix in the mix cabinet is
too cold.
a. The mix cabinet
refrigeration system needs
adjustment.
a. Contact a service
technician.
---
7. Excessive mix leakage
from the bottom of the
door spout.
a. Worn, missing or incorrect
o-ring is on the draw
valve.
b. Check the o-rings.
(Replace every 3 months.)
41
b. Improper lubrication on
the draw valve o-rings.
c. Lubricate properly. 19