Operation (Continued)
3 Emergency "Stop" Switch
The two emergency "Stop" switches are
mounted for operator convenience, on both
sides of the case sealer. Pushing either of
these switches will stop the drive motors/belts
and exhaust air from the flap kicker.
To restart machine, rotate emergency stop
switch (release switch latch) and then restart
machine by pressing green (On) button on side
guard.
4 Height Adjustment Crank, Upper
Taping Head
Raises and lowers upper taping head/flap
folders to accommodate box height.
5 Width Adjustment Crank
Adjusts distance between side drive belts to
accommodate box width.
6 Top Flap Compression Rollers
Rollers adjust to properly maintain box width/
top flap center seam for tape seal.
7 Indicator, Air Pressure
The optical warning indicator, located on the
upper flap folder frame, indicates "Red" when
compressed air circuit is on.
8 Box Gate Air Pressure Regulator
Adjusts lifting force of the box gate depending
on the weight of boxes being sealed.
9 Gate Cams Figure 3-4
The gate cams A B control the rate of box
entry into the case sealer. Depending on box
size, gate cams can be adjusted to increase
production rate. See "Adjustments – Gate
Operation", page 29.
10 Kicker Cam Figure 3-4
The minor flap folder, controlled by the kicker
cam C , closes the trailing minor flap on the
box. The kicker cam must be adjusted
according to the length of the box being
sealed. See "Operation", page 20,
Figure 3-8.
11 Pocket, Instruction Manual
A pocket is provided inside the right door for
storage of the machine instruction manual.
Keep the manual in this pocket for the
convenience of machine operators.
Figure 3-4 – Gate/Kicker Cams
Figure 3-3 – "On/Off" Valve/Regulator/Filter