28
Maintenance (Continued)
WARNING – Turn air and electrical supplies off and disconnect before beginning
maintenance. Failure to comply with this warning could result in severe personal injury or
equipment damage.
WARNING – The following procedure
must be performed by trained service
personnel because of the high voltage
electrical hazard within the control box.
Circuit Breaker
The case sealer is equipped with a circuit breaker
which trips if the motors are overloaded. Located
inside the electrical control box on the side of the
machine, the circuit breaker has been pre-set at
2.2 Amps and requires no further maintenance.
Air Line Filter – Figure 4-5
Periodically check the air line filter to drain water
and clean as necessary. Do not allow water to go
above the filter element.
Figure 4-5 – Air Line Filter
If circuit is overloaded and circuit breaker trips,
unplug machine from electrical power:
1. Determine cause of overload and correct.
2. Remove electrical enclosure cover.
3. Press the red "Reset" button and then the
green "Start" button.
4. Replace cover.
5. Plug in machine. Wait two minutes.
6. Press machine "On" button, on the side
guard, to resume case sealing.
Knife Replacement, Taping Head
See Section II, "Maintenance – Blade (Knife)
Replacement", page 9.