Everpure 2001 Hot Beverage Maker User Manual


 
SUPREMA 2001 - OPERATION & SERVICE MANUAL
Suprema 2001 - Operation & Service July 6, 2001 Page 15 of 60
TOTAL COUNTER RESET
This software contains a special access code that enables the service person to reset all
the counters to zero, including the "
VEND TOTAL
" counter. This operation should be
performed before a unit is re-installed in the field.
1. To perform a "
TOTAL COUNTER RESET
",
a) Switch the power to the coffee maker "
OFF
" (switch is at the rear of the
unit).
b) Press the "
SET
-
UP
" mode button on the inside door panel and keep it
depressed.
c) With "SET
-
UP" mode button pressed, switch power to coffee maker "ON".
d) The following message will now appear on the display,
e) Enter the "
TOTAL COUNTER RESET
" access code (described below).
"TOTAL COUNTER RESET" ACCESS CODE
The following is the factory preset "
TOTAL COUNTER RESET
" access code - press the
following in the sequence outlined below;
1 COFFEE
2 MILD STRENGTH
3 LARGE CUP
4 MEDIUM CUP
5 SMALL CUP
Once the access code has been entered, a counter will appear on the top left of the
display, and will quickly increment from 0 to 255. Once this is complete, press
START” for the brewer to cycle once to re-establish its home position.
ENTER ACCESS
CODE:
!
Note:
When the reset is
complete, the unit
will automatically
exit to the
“standby” mode,
and the internal
light will remain
ON
” temporarily.