Everpure 2001 Hot Beverage Maker User Manual


 
SUPREMA 2001 - OPERATION & SERVICE MANUAL
Page 32 of 60 July 6, 2001 Suprema 2001 - Operation & Service
GENERAL INFORMATION
There are several features with this version of software that you should be aware of,
and these features are outlined below.
'
If an overflow occurs during a hot chocolate cycle, the machine will stop
immediately (anywhere in mid cycle). If an overflow occurs during a
coffee vend, the cycle will be completed (without any pauses), and then
the unit will stop.
'
A rear overflow will shut everything off, including the heater element. A
front overflow will shut off all motors and valves, but will leave the
heater element active until the water level drops below the level probes.
Power to the element will then be switched off.
'
The "TANK IS FILLING
" message appears immediately when the unit is
powered up (if tank is not full). The "
CHECK WATER SOURCE
" message
appears if the tank has not been completely filled after five minutes.
'
There are two fuses in the fuse box. The 5-amp fuse protects electronics,
motors and valves. The 15-amp fuse protects the heater circuit.
'
There is only one limit switch for the brewer motor. This switch controls
both the pause and the home position. If the brewer does not read the
home position, it will run a dry cycle (no water or product) and stop once
it reads the home position. If the home position is not found within 24
seconds, the brewer motor will stop and an error message will appear.
'
If the chocolate pump falls out of the home position, it will automatically
cycle until it reads the home position, and then it will stop. If the home
position is not found within 8 seconds, the pump will stop and an error
message will appear on the display.
'
If any blue component harness is not connected to the rear board, a
message will appear advising you of the problem. The system will be
disabled until the harness is re-connected (with the main power off).
'
The water tank does not have a mechanical level float and switch. It uses
three water level probes – two to activate the inlet valve and a safety
probe in case the first two get covered in lime/calcium (which causes the
level in the tank to increase too high).
'
After a chocolate pump cycle is complete, the valve will open for 0.2
seconds to rinse the chocolate components.
'
When a mixed beverage is selected (café mocha or mixed powder
beverage), it is mixed with regular strength coffee only. It cannot be
mixed with decaf, and the strength cannot be changed.
'
As a safety feature, if the "START" button gets jammed (while pressed)
an error message appears - the unit will not continuously brew cups.
!
Note:
Updates to this
information will be
issued as soon as
any changes are
made and
implemented into
the programming.