3–5
3. At the programmed shake time, an audible alarm will sound and the display will flash SHAKE.
After shaking the basket, press the corresponding cook switch,
1
or
2
, to cancel the alarm.
0. After the completing the cooking time, an audible alarm will sound and the display will flash
pull. Remove the indicated basket and press the corresponding cook switch,
1
or
2
, to cancel
the alarm. If no other products are being cooked in the frypot, the display shows 7:00 QA
indicating that the quality timer is counting down. If the quality time is set for some time other
than 7:00 minutes, the display starts counting down from that time. (QA is not available for
McChicken, Crispy Chicken or Filet-o-Fish).
0. When the quality time expires, an audible alarm will sound, and the display will flash
QA. Cancel
the alarm by pressing the corresponding cook switch,
1
or
2
.
NOTE: When you initiate a new cook cycle, the quality time will automatically reset.
3.4 M-100B™ Computer Problem Condition Indicators
Open Drain Valve Indication
If, when the ON/OFF switch is pressed to the ON position, the display reads IGNITION
FAILURE, verify that the drain valve is fully closed. A drain safety switch built into the drain valve
assembly prevents the elements from being energized if the valve is not completely closed. After
verifying that the valve is fully closed, turn the computer OFF* for at least 5 seconds, then turn it back
on. If the message reappears, there is a problem in the electrical circuitry of the fryer or the computer;
contact your Frymaster Factory Authorized Service Center (FASC).
* On early-version M-100B split-vat units, BOTH computers must be turned off, even though the
problem condition may be associated with only one vat.
Low Temperature Indication
If the frypot temperature drops to more than 45°F (25°C) below the programmed setpoint temperature
during the cooking cycle, the cook switches will lock, the display will flash lOW TEMP and an
audible alarm will sound. If the frypot temperature returns to a range between 45°F (25°C) to 15°F
(8°C) of setpoint, the audible alarm will stop, but the cook switches remain locked and the display
alarm continues flashing. All functions return when the frypot temperature is within 15°F (8°C) of
the programmed setpoint.
Probe Failure Indication
If the temperature probe fails, the display will flash PROBE FAILURE and an audible alarm will
sound. To cancel the alarm, turn the computer OFF. In split-vat fryers, turn off the side in which the
failure occurred. If a probe fails during the high-limit test, PROBE FAILURE is displayed.
NOTE: If the temperature probe fails in the left side of a split-vat, that side cannot be turned back
ON once it has been turned OFF.