Frymaster H14 Series Fryer User Manual


 
6-3
Fryer Heating Oil
COMPUTER
PANEL OPEN
INTERFACE
BOARD VISIBLE
Initiate HEAT MODE by
turning the fyrer on and setting
the temperature at least 45° F
(24° C) above the temperature
of the cooking oil.
Is the HEATING MODE indicator lit with LOW TEMP
displayed in computer window?
NOTE:
Indicator may cycle on and off and LOW TEMP
may alternate with the product name.
1. Product name displayed constantly indicates
oil temperature is within 45° F (24° C) of set-
point.
2. HOT HI 1 indicates the oil temperature is
higher than 410° F/210° C (395° F/202° C for
European Community).
3. 3. PROBE FAILURE indicates a problem in
the temperature-measuing circuitry, including
the probe.
4. IGNITION FAILURE indicates a problem with
the latching relay on the interface board or
the latching contactor.
Probable causes are:
1. Defective computer
2. Broken or improper wire connection
NO
YES
Is the 3-phase power cord plugged in properly?
Is the circuit breaker in the 3-phase circuit closed?
Probable causes are:
1. Unplugged 3-phase power cord
2. Defective or shorted circuit
NO
Continued on
next page
YES