3–12
6. To EXIT and SAVE the product name entry, press the switch. SAVE will flash in the right
display, followed by YES or NO, indicating whether the menu item is active or not. Press the
right
1
or
2
switch to toggle between yes and no.
7. Press the switch to cycle through the Duty Times, Pull Time, QA (hold) Time, and Cooking
Temperature Setpoint settings. Program the times and the set point in accordance with the section
that follows.
How to Program Duty Times, Pull Time, QA Time, and Setpoint for a Test Menu Item
NOTE: Duty Time refers to an operator-specified time within a cooking cycle when the computer
will sound an alarm to prompt a particular duty such as shaking the basket.
1. Enter the program mode. See How to Enter the Program Mode on page 3-10.
2. Press the switch to select the desired test menu.
3. Press the switch. DUTY1 will appear in the left display. The currently programmed time
appears in the right display. To program the time, use the following switches:
Left
Minutes (in increments of ten)
Left
1
Minutes (in increments of one)
Left
2
Seconds (in increments of ten)
Right
1
Seconds (in increments of one)
Press the right
2
switch to toggle between the manual alarm cancel mode (MAN) and the
automatic alarm cancel mode (AUTO).
NOTE: In the automatic alarm cancel mode (AUTO), when the programmed time has elapsed,
an audible alarm will sound three times and then stop. In the manual alarm cancel mode (MAN),
when the programmed time has elapsed, an audible alarm will sound until the operator presses the
cook switch (
1
or
2
) that was pressed to start the cooking cycle.
4. Press the
switch, DUTY2 appears in the left display. The currently programmed time appears
in the right display. Program the time in the same manner as Duty1 time.
NOTE: Enter a time of 00:00 to bypass this option.
NOTE: In the steps that follow, Pull Time refers to the programmed time at which the product is
fully cooked and an audible alarm will prompt removal of the basket from the cooking oil. QA
Time refers to the maximum time that a product may be held after the cooking cycle has
completed.
5. Press the switch to display PULL in the left window. Program the pull time in the same
manner as the duty times.
6. Press the
switch to display QA in the left window. Program the QA time in the same manner
as the duty times.