Liebherr RI 1410/ RBI 1410/ FI 1051 Refrigerator User Manual


 
Fig. 8
- An effective ventilation cross-section of at least 31 in
2
(200 cm
2
) per unit must be present at the air intake
Fig. 8 (1)
and air outlet
Fig. 8 (2)
.
- The upper ventilation cross-section can be set up
directly above the appliance with an optional ventilation
grille
Fig. 8 (2)
, near the ceiling above a cabinet
Fig. 8 (3)
or as an air vent in an intermediate ceiling
Fig. 8 (4)
.
Fig. 9
- An unobstructed air way with a depth of at least
1 1/2 in. (38 mm) must be ensured at the back of the
kitchen cabinet.
u
The air-circulation clearances indicated above must be
maintained.
6 Door swing clearance
Frameless cabinets: The casing trim overlaps the
cabinets at the side and top. Cabinets may require filler
strips to prevent interference with the cabinet door swing.
The door opening must allow for filler strips.
The factory setting for the door to swing open is 110°. The
optional setting for the door to swing open is 90°. Use the
following illustrations (1:1) to ensure other cabinets or
counters do not interfere with the door opening.
Door swing clearance
8