TCM Error Messages
TCM validates the cells in the partition table when the Execute button is clicked. Cells highlighted in
red contain an error. Partition loading is disabled until all errors are corrected.
Table 10-3. TCM Error Messages
Error Description/Solution
Failed to build images: flash file
system DLL not loaded!
TCM could not load the DLL required to build images for the targeting flash file
system. Reinstall TCM or recover the DLL.
Failure finding directory xxx Building process failed because directory xxx was not found.
Failure creating volume Building process failed because a certain disk volume could not be created.
Failure adding system file to
image
Build process failed because TCM failed to add a certain system file to the disk image.
INVALID PATH The path for the image file to build is not valid.
Nothing Selected To Build In the Config Build window, no item is selected to build.
Illegal ESS ID In the Build ESSID Partition window, no ESS ID was entered or the ESS ID entered was
illegal.
Disk Full TCM failed to create Hex image file at the selected path. Check available disk space.
Target Disk Full Build process failed because TCM failed to add file to the image of a disk volume.
Remove some files or increase the disk size.
Hex file is READ ONLY The Hex image file to be created exists and is read-only. Delete the existing file or
change its attribute.
Error opening the file xxx with
write access
TCM could not open file xxx with write access. Check if file is in use.
Failure creating binary file TCM failed to open/create an intermediate binary file.
Hex File To load is missing or
invalid
In Load Terminal window, the file selected to load has invalid status.
Could not locate terminal name in
TCM.ini file
While loading the Script Properties window, TCM could not find the TCM.ini section
corresponding to the terminal type specified by the current opening script. Either
TCM.ini or the script file is invalid.
Incorrect disk sizes in TCM.ini file The total disk size specified in the script does not match the total disk size defined in
the corresponding TCM.ini section. Check if the script is corrupt or the TCM.ini has
changed after the script was created.
INVALID DIRECTORY In Script Properties window, the selected System File Path is not a valid directory.