Symbol Technologies MC9000-S Water Dispenser User Manual


 
Mobile Computer Configuration
10-25
Invalid data in HEX file -25 The Symbol HEX file being downloaded contains
invalid data. Ensure the file is in proper Symbol HEX
file format with valid HEX data.
Exceeded max size -26 The download file is too large to fit into the space
allocated for it. Either make the file smaller or increase
the space allocated for it by altering the partition
table.
Partition is not valid on this device -27 The downloaded file specifies a partition entry that
does not exist on the device. Only download files that
are valid for this device, or change the partition table
so that the new file is valid on the device.
Wrong destination code -28 A specific partition was chosen from the Main Menu
(not Auto Select) but the file selected for download
was for another partition. Ensure that the partition
selected from the Main Menu matches the file
selected for download.
File type does not support IPL Auto
Select
-29 Monitor, Power Micro and Partition Table cannot be
loaded with Auto Select. Select the appropriate area,
and try again.
Non-contiguous record found -30 A Symbol HEX file download was attempted but the
HEX file is invalid. Ensure the file is in Symbol HEX file
format.
Timed Out - No data -31 IPL was waiting for data from the source device but
timed out before receiving any. Check the source
device connectivity and retry.
Fail: Buffer Overrun -32 The serial port device could not keep up with incoming
data. Retry the serial download with a lower baud
rate.
Partition Table not Valid -33 The size of flash memory is different than that
described in the partition table. Retry the download
with the correct partition table file.
Invalid file format -34 The file format is invalid. Only Symbol HEX files are
supported by IPL.
Table 10-4. IPL Errors (Continued)
Error Text Error Number Probable Cause