Vulcan-Hart ML-136059 Electric Steamer User Manual


 
MODEL C24EA - THERMOSTATS AND HIGH LIMITS
F35453 (July 2008)Page 13 of 68
8. Remove capillary tube from heating element.
Installation
1. Route capillary bulb through the opening in
heating element mounting plate. Ensure there
are no sharp bends in capillary tubing while
installing.
A. Insert capillary bulb into the holding tube
on heating element.
2. Apply pipe thread sealant to threads then install
large capillary tube mounting nut.
A. Ensure capillary bulb is centered in the
holding tube. Tighten the capillary tube
compression nut.
3. Install heating element with a new gasket.
Torque mounting nuts to 70 in-lbs and tighten
using an alternating pattern.
4. Secure high limit to low voltage control box then
coil excess capillary tube length near the high
limit.
5. Check steamer for proper operation and leaks
around heating element gasket and high limit
capillary tube nuts.
CONDENSATE THERMOSTAT
1. Turn off machine to drain steam generator.
Allow steamer to complete drain cycle.
A. Turn off water supply.
2. Remove RIGHT SIDE BASE PANEL as
outlined under COVERS AND PANELS.
3. Disconnect electrical wiring to condensate
thermostat.
4. Remove condensate thermostat from the rear of
drain box.
5. Reassemble parts removed in reverse order.
Apply pipe thread sealant to threads of
thermostat before assembly.
6. Check steamer for proper operation and leaks
around condensate thermostat.
RIGHT SIDE SHOWN
REAR OF DRAIN BOX SHOWN