MODEL C24EA - CONTROL BOARD
F35453 (July 2008) Page 32 of 68
CONTROL BOARD
REMOVAL AND REPLACEMENT
1. Remove FRONT BASE PANEL as outlined under COVERS AND PANELS.
2. Disconnect electrical connectors from control board.
3. Squeeze tab on plastic standoffs (10) to release control board.
4. Reassemble parts removed in reverse order.
5. Check steamer for proper operation.
NOTE: When installing, ensure the board jumpers are set to factory defaults as follows: Delime time delay relay
jumper set to 60 minutes; drain time delay relay jumper set to 3 minutes; and machine type set to floor model.